Line 36: Line 36:
  * NodePrinceton - had been switched from Comcast to WiLine and issue with DHCP handoff   * NodePrinceton - had been switched from Comcast to WiLine and issue with DHCP handoff
  * NodeWeidler - WDR3600-16M (mod), cable modem (surfboard) rebooted (4:10am)

Location: Jitsi
Date and Time: Wednesday, March 24, 2021, 5:30pm-8:00pm
Scribe: You
Roll Call: RussellSenior,TomasKuchta,SteveTree,TedBrunner,JasonBergstrom

Agenda

  • Pick location for next weekly
  • Updating gateway firmware, so far:
    • Meraki MR24
    • Buffalo WZR600DHP
    • PC Engines Alix2
    • Netgear WNDR3800
    • TP-Link WDR3600 (16MB)
    Left to do:
    • Ubiquiti ERX
    • D-Link DIR806L
    • PC Engines APU
  • Node Notes:
    • NodePrinceton -- initial flash had a bug in the hand-curated modifications to the files overlay, which lead to the pre-auths for a tenant not working. When I corrected this manually, in some kind of weird coincidence, the DHCP server on the upstream Stephouse/WiLine router stopped offering leases and I lost remote access. Took a couple hours to figure out what was going on and to adopt a static configuration. Should be on the lookout for this kind of failure at other Stephouse networks (already have a static configuration at NodeKellogg as well)

    • NodeWeidler -- update to the WDR3600-16M device didn't "come back up". Investigating at about 4:15 am, discovered the flash had gone fine, but the cable modem was not handing out DHCP lease (maybe a macaddr change??), power cycled the cable modem and it started working again. Possibly freaked out the residents upstairs. Left before the police arrived. ;-) -- RussellSenior

    • NodeStreetRoots -- had a problem flashing remotely, needed an onsite visit and retry, recovered.

    • NodeAnholt -- we don't manage it, but it moved and gear got improved, per wiki edit.

  • Stephouse/wiline machne is offline, working to recover.
  • FCC - Share Your Broadband Experience - https://www.fcc.gov/BroadbandData/consumers

  • Your Item Here

Notes

  • Discussions on how to leverage the Recovery Act money
    • City and PPS are interested in network deployment
    • Staffing, and embedding volunteer positions in orgs/cities
    • $10M pilot suggested by Russell
  • Node notes
    • Many more platforms flashed by Russell
    • NodePrinceton - had been switched from Comcast to WiLine and issue with DHCP handoff

    • NodeWeidler - WDR3600-16M (mod), cable modem (surfboard) rebooted (4:10am)


[CategoryMeetingNotes]